25 CYB-KLED CyberSuite Installation Manual
Use this to set the zone type for a motion detector
that is located in an entrance area.
4 Instant Zone will cause an alarm immediately.
5 24HR Zone will always cause an alarm immediately.
6 Fire Zone is a fire zone and will generate an instant
alarm.
7 Fire Delay Zone is a delayed fire zone and will generate the
fire delay beeping and require the user to follow
the delay fire zone procedures to prevent a full fire
alarm from being activated.
Zone Options
The zone options select functions that relate to the operation of
bypassing, force arming and stay arming.
Once you have selected a Zone Type for your selected zone, you
must select the Zone Options.
To toggle options press the keys [1] to [8] , and the corresponding
Zone LED will be lit when that option is ENABLED.
Pressing the [ENTER] key will save the options.
Option 1 - Bypass Allowed
5 Enabled the zone can be bypassed. A fire zone can
never be bypassed regardless of the bypass setting.
6 Disabled zone can not be bypassed.
Option 2 - Stay Zone
5 Enabled the zone is set as a stay zone. When the
system is armed in stay mode this zone will not
generate an alarm.
6 Disabled the zone is not a stay zone.